Elmo
867.png

Hardwired Intrusion Detection

RMI01

Stand-alone microphone impact detector with thermal tamper detection device

The RMI01 is a stand-alone microphone impact detector. It is based on a new technology that combines all the advantages of a PIEZO transducer with those of a MEMS accelerometer in a single seismic sensor. The result is a detector capable of consistently delivering maximum performance without lengthy and complex calibration procedures. It guarantees protection for all types of walls (brick, reinforced concrete, tuff, etc.) as well as safes, ATMs, and cash registers. It also features an integrated thermal tamper detection device. Configuration and calibration are extremely simple and can be performed using an optional Wi-Fi dongle (RMIDNG) connected to the detector and the dedicated RMISETUP app for smartphones/tablets. The RMI01 implements sophisticated analysis algorithms to recognize different attack techniques against the protected structure: burglary (weak impacts), breakage (strong impacts), breakthrough (single, very strong impacts), and continuous vibrations (cutting or drilling with power tools). It also features anti-removal and anti-opening tamper protection, thermal tamper protection, programmable periodic self-test, and operational test. No mounting plate is required for correct sensor operation. An optional universal mounting plate (RMIBRK) is available for installation on uneven walls. It is certified to EN 50131-2-8 grade 3, environmental class II.

Features


Installation On sight
Product type Seismic sensor
Application Walls or safes
Technology Impact+Microphonic

Technical details


Versions
Default PPRSIMP00200
Range/area Up to 46 m2
Material White ABS
Installation On any type of wall
Adjustments Configuration and calibration via Wi‑Fi dongle (RMIDNG) to be connected to the detector and APP for mobile devices
Functions Protection from weak impacts, strong impacts, breaking and continuous vibrations
Anti-removal and anti-opening tamper, thermal tampering, programmable periodic self-test, operational test
Terminals Power supply
Operational test inputs and ARM memory
Alarm outputs (continuous vibration, weak shock, strong shock and breakthrough), self-test or operational test failure, insufficient power supply, tampering
Dimensions L 89 × H 89 × D 20 mm
Weight 53 g
Power supply From 8 Vdc to 16 Vdc (nominal voltage 12 Vdc)
Current consumption 20 mA, 50 mA max
Operating temperatures −20 / +70 °C
Degree of protection IP40
Certifications EN 50131‑1, EN 50131‑2-8 grade 3, environmental class II

Technical documentation


Select the type of documentation you want to see

Available Documents: 7

Manuale Tecnico
Version: -
12/05/2026
Technical Manual
Version: -
06/02/2026
Datasheet
Version: 20260402030638
02/04/2026
Foglio tecnico
Version: 20260402030646
02/04/2026
Product Description
Version: 20260402030634
02/04/2026
Descrizioni Capitolato
Version: 20260402030642
02/04/2026
Notified Body
Version: 1
12/05/2026